Blog

How to Run an IEC 62443 Gap Assessment, Step by Step

How to Run an IEC 62443 Gap Assessment, Step by Step

An IEC 62443 gap assessment compares the security an industrial automation and control system (IACS) has today with the target security level set for each of its zones and conduits. You get the targets by following the risk assessment steps in IEC 62443-3-2. You then check the system against the requirements in IEC 62443-3-3. The output is a ranked list of gaps that feeds the cyber security requirements specification and an action plan. What the standards ask for Neither standard defines a "gap assessment" as such. The method below is how the two parts fit together. IEC 62443-3-2 sets out zone and conduit requirements (ZCRs), numbered ZCR 1 to ZCR 7. Together they cover defining the system, partitioning it into zones and conduits, assessing risk, setting a target security level and documenting the result (IEC 62443-3-2:2020, Clause 1). IEC 62443-3-3 gives the technical system requirements (SRs). They sit under seven foundational requirements (FRs). Each SR has a baseline requirement and may have requirement enhancements (REs), and each is mapped to a capability security level from 1 to 4 (IEC 62443-3-3:2013, 3.3). A security level (SL) is a measure of confidence that a system, zone or conduit is free from vulnerabilities and works as intended (IEC 62443-3-2:2020, 3.1.15). Annex A of IEC 62443-3-3 says the same approach works for new systems and for existing ones. You split the system into zones and conduits, give each a target, then design or redesign to meet it (IEC 62443-3-3:2013, A.2.3). Step 1: Define the system under consideration (ZCR 1) The system under consideration (SUC) is the defined set of IACS assets needed to provide a complete automation solution, including the network infrastructure (IEC 62443-3-2:2020, 3.1.17). It can include a basic process control system, a safety instrumented system, SCADA and packaged equipment from suppliers. You must clearly identify the SUC, mark its security perimeter and identify every access point (IEC 62443-3-2:2020, ZCR 1.1). Use the asset inventory, architecture and network diagrams and the data flows. If the access point list is weak, everything after it will be weak too. Step 2: Initial risk assessment and zones and conduits (ZCR 2 to ZCR 4) The initial risk assessment finds the worst case, unmitigated risk if the SUC were compromised (IEC 62443-3-2:2020, ZCR 2.1). Impacts are usually judged in terms of health, safety, environment, production, financial loss and reputation. For hazardous processes, the standard advises drawing on the process hazard analysis and the functional safety assessment. A corporate risk matrix is the usual tool, and Annex B gives examples. Next, group assets into zones and conduits (IEC 62443-3-2:2020, ZCR 3.1). The grouping is based on risk or on criteria such as criticality, operational function, location, required access or the responsible organisation. ZCR 3.2 to ZCR 3.6 ask you to keep business assets apart from IACS assets. They also ask you to separate safety related assets, temporarily connected devices, wireless devices and devices connected through external networks. Then compare the initial risk with the organisation's tolerable risk. If it exceeds tolerable risk, a detailed risk assessment is required (IEC 62443-3-2:2020, ZCR 4.1). Step 3: Detailed risk assessment and SL-T (ZCR 5) ZCR 5 applies to every zone and conduit. It runs from threats (ZCR 5.1) and vulnerabilities (ZCR 5.2) through consequence, likelihood and unmitigated risk (ZCR 5.3 to ZCR 5.5). A target security level (SL-T) must then be set for each zone and conduit (IEC 62443-3-2:2020, ZCR 5.6). It can be a single value or a vector with one value per FR. The standard does not prescribe a method. One approach it describes uses the risk matrix. You start from a reasonable estimate of the SL, check whether the risk is acceptable, and raise the SL until it is. The remaining steps look at existing countermeasures (ZCR 5.8), re-evaluate likelihood and impact (ZCR 5.9) and give residual risk (ZCR 5.10). Residual risk is compared with tolerable risk (ZCR 5.11), and further countermeasures are found where needed (ZCR 5.12). The results are documented (ZCR 5.13). Step 4: Compare the system with its targets This is the gap check itself. For each zone and conduit, take the SL-T for each of the seven FRs: FR 1 Identification and authentication control FR 2 Use control FR 3 System integrity FR 4 Data confidentiality FR 5 Restricted data flow FR 6 Timely response to events FR 7 Resource availability Annex B of IEC 62443-3-3 maps every SR and RE to the FR security levels 1 to 4. For each one required at the target level, record whether the zone meets it natively, meets it through a compensating countermeasure, or does not meet it. For an existing system you are judging the achieved security level (SL-A). For new or replacement products you also need the supplier's capability security level (SL-C) for each FR. Compensating countermeasures are allowed, but they must follow IEC 62443-3-2 (IEC 62443-3-3:2013, 4.3). They should be documented so that the SL-A properly reflects the design (IEC 62443-3-3:2013, 0.2). Check every proposed fix against the essential functions rule. Security measures must not adversely affect the essential functions of a high availability IACS unless a risk assessment supports it (IEC 62443-3-3:2013, 4.2). For example, accounts used for essential functions must not be locked out. Record each gap with the zone or conduit, the FR, the SR or RE, the current state and a proposed countermeasure. Step 5: Prioritise, document and approve (ZCR 6 and ZCR 7) Rank the gaps by residual risk against tolerable risk. For each risk that exceeds tolerable risk, the organisation decides whether to accept, transfer or mitigate it in line with its policy (IEC 62443-3-2:2020, ZCR 5.11). Moving an asset into a better protected zone is also a valid fix (IEC 62443-3-2:2020, ZCR 5.12). The cyber security requirements specification (CRS) records the mandatory countermeasures (IEC 62443-3-2:2020, ZCR 6.1). It must cover: the SUC description zone and conduit drawings the characteristics of each zone and conduit, including its SL-T operating environment assumptions the threat environment organisational security policies tolerable risk regulatory requirements These are ZCR 6.2 to ZCR 6.9. The CRS does not have to be a single document. Finally, the asset owner managers who are accountable for the process must review and approve the results (IEC 62443-3-2:2020, ZCR 7.1). The gap list, with owners and dates, becomes the action plan. Keep it current A gap assessment is a snapshot. Achieved security falls over time as countermeasures degrade, new vulnerabilities appear and threats change (IEC TS 62443-1-1:2009, 5.11.2.3). IEC 62443-3-3 advises re-evaluating the system during or after modifications and on a regular schedule (IEC 62443-3-3:2013, A.2.3). Where ControlShield can help ControlShield can run the IEC 62443-3-2 risk assessment and the IEC 62443-3-3 gap check for your system. We can also write up the CRS and the action list in a form your engineers can use. Sources IEC 62443-3-2, Security for industrial automation and control systems, Part 3-2: Security risk assessment for system design, Edition 1.0, 2020 IEC 62443-3-3, Industrial communication networks, Network and system security, Part 3-3: System security requirements and security levels, Edition 1.0, 2013, with Corrigendum 1, 2014 IEC TS 62443-1-1, Industrial communication networks, Network and system security, Part 1-1: Terminology, concepts and models, Edition 1.0, 2009

← All posts

Talk to us about your OT systems

Get in touch to discuss your requirements or to book your free OT Cyber Security Appraisal.