OT cyber security for offshore wind and renewables

Wind farms, solar parks and battery sites are run remotely, maintained by original equipment manufacturers (OEMs) and connected to the grid through substations that many parties touch. ControlShield helps developers, operators and their contractors build cyber security into renewables projects and meet NIS expectations where they apply.

Sectors › Offshore wind and renewables

Last checked: 24 November 2026.

The OT cyber risks on renewables sites

  • OEM remote monitoring and control. Turbines and inverters are usually monitored and supported by the manufacturer over remote links. In February 2022 a satellite network outage cut remote monitoring for around 5,800 Enercon turbines in central Europe. The turbines kept generating in automatic mode, but the incident showed how much depends on one communications path.
  • Many parties, one site. Developers, OEMs, the offshore transmission owner, the operations and maintenance contractor and the grid all have systems that meet at the substation and control centre. Each boundary needs an owner.
  • Long construction phases. During construction and commissioning, many contractors connect laptops and equipment. Weak controls at this stage often stay in place once the site is running.
  • Remote and hard to reach. Offshore assets can't be visited quickly, so a cyber incident that needs someone on site becomes a long outage.
  • More connected devices. Battery storage, solar inverters and flexibility services add devices and cloud platforms that can affect output and the grid.

Which UK rules apply to renewables

Rule or framework What it means for you
NIS Regulations 2018 (electricity subsector) Applies at the 2 gigawatt generation threshold and to qualifying offshore transmission licence holders. Duties to manage risk to network and information systems and report significant incidents.
Ofgem NIS guidance for downstream gas and electricity (v3.0, January 2026) How Ofgem expects in-scope operators to meet and evidence NIS duties using the NCSC Cyber Assessment Framework (CAF).
Cyber Security and Resilience Bill Adds large load controllers, widens incident reporting and lets regulators designate critical suppliers. See our CS&R Bill guide.
NCSC Cyber Assessment Framework The framework Ofgem uses for NIS. Also a useful benchmark below the threshold. See our CAF 4.0 guide.
EU NIS2 Directive Covers electricity producers in EU member states. Relevant if you also develop or operate assets in the EU.
IEC 62443 The standard series most often used to set cyber requirements for control systems and their suppliers.

How ControlShield helps renewables projects

  • Security from FEED onwards. Cyber security requirements and target security levels set early, so OEM packages, substations and control centres are bought secure rather than fixed later. Project lifecycle support
  • OEM and supplier evidence. Asking for, and checking, evidence against IEC 62443-2-4 (integrators and service providers) and IEC 62443-4-1 and 4-2 (product suppliers). Our supplier procurement guide explains how.
  • Remote access design. Secure, auditable remote access for OEMs and contractors, following the NCSC's secure connectivity principles for OT.
  • Risk assessments. IEC 62443-3-2 risk assessments of wind farm SCADA, substation systems and control centres. Risk assessments
  • NIS and CAF. CAF self-assessments and improvement plans for operators in scope. Regulatory assistance

What carries over from offshore oil and gas

Our hands-on project work is in upstream oil and gas and downstream gas distribution, not wind. Much of it carries straight over:

  • Offshore operations. Remote installations, limited bandwidth, long travel times and strict permit-to-work control are everyday conditions in offshore oil and gas.
  • Packaged OEM equipment. Oil and gas projects are full of vendor-packaged control systems with their own remote support, the same model as turbines and inverters.
  • Security built into projects. We write cyber requirements into specifications and check them at factory and site acceptance, which is exactly where renewables projects need them.
  • The same standards. IEC 62443 and the NCSC CAF apply in the same way whatever the energy source.

Frequently asked questions

Are offshore wind farms covered by the NIS Regulations?

Some are. In Great Britain the NIS threshold for electricity supply includes undertakings whose generation, together with affiliated companies, totals 2 gigawatts or more of transmission-connected capacity. Offshore transmission licence holders are in scope where their systems connect to 2 gigawatts or more of generation. Many single projects fall below these thresholds, but owners with large portfolios may not.

Who regulates cyber security for wind farms?

Where a wind farm owner or offshore transmission owner is an operator of essential services, DESNZ and Ofgem are the joint competent authority and Ofgem carries out day-to-day compliance work. Outside NIS, there is no specific cyber regulator, but customers, contracts and insurers may set their own requirements.

Does HSE's OG86 apply to wind farms?

OG86 is HSE's guidance for inspecting control system cyber security at major hazard sites, such as COMAH establishments and offshore oil and gas installations. A typical wind or solar farm is not a major hazard site, so if you're in NIS scope the NCSC CAF, applied by Ofgem, is the framework you're most likely to be assessed against.

How should we secure OEM remote access?

Start by knowing every remote connection that exists. Then route them through one controlled, monitored access point, use individual accounts with multi-factor authentication, and allow access only when it's needed. The NCSC's secure connectivity principles for OT set out the approach.

When should cyber security start on a renewables project?

At FEED or earlier. Setting cyber requirements and target security levels before OEMs and contractors are appointed is far cheaper than changing equipment after it's installed.

Sources

Other sectors we support

Free OT cyber security appraisal

How the free appraisal works

  1. Complete the checklist

    Download the free readiness checklist and work through the 35 questions with your control systems team.

  2. Talk it through

    Send it to us and we'll arrange a free 30-minute call within 10 working days to go through your answers.

  3. Get your next steps

    Within 5 working days of the call, we'll send you a follow-up email with your priorities and suggested next steps.

The appraisal is a conversation and a follow-up email. It is not a formal assessment, audit or regulatory submission. No access to your systems is needed.

Building or running a renewables project?

Free OT cyber security appraisal: complete our readiness checklist, then talk it through with us on a 30-minute call.