Production lines, chemical plants and process sites depend on control systems that were rarely designed with cyber attacks in mind. ControlShield helps manufacturers and process operators protect production and safety, meet HSE's expectations at COMAH sites, and answer the security questions their customers now ask.

Sectors › Manufacturing and process plants

Last checked: 24 November 2026.

The OT cyber risks on the plant floor

  • Ransomware crossing from IT to OT. Flat networks and shared accounts let an infection on business systems reach production systems, or force a shutdown because nobody can tell whether it has.
  • Legacy operating systems. Operator stations and engineering workstations often run old Windows versions that can't be patched without vendor approval.
  • Remote vendor access. Machine builders and system integrators often support equipment remotely, sometimes through connections the site doesn't know about.
  • Safety instrumented systems. At chemical and process plants, safety systems must stay independent and protected, because a compromise can lead to a major accident.
  • Connected sensors and cloud platforms. Industrial internet of things devices and analytics platforms add new paths into the plant.

Which UK rules apply to manufacturers

Rule or framework What it means for you
COMAH Regulations 2015 and HSE OG86 At COMAH establishments, HSE expects control system cyber security to be managed as part of major accident prevention, benchmarked against OG86. See our CAF 4.0 and OG86 guide.
NIS Regulations 2018 Do not apply to most manufacturers. Refineries and large oil and gas processing facilities can be in scope under the oil and gas subsectors.
Cyber Security and Resilience Bill Regulators will be able to designate critical suppliers to essential services. If you supply energy, water or other essential services, your customers will pass more requirements down to you. See our CS&R Bill guide.
EU Cyber Resilience Act Security requirements and vulnerability reporting for products with digital elements sold in the EU, including many industrial products.
EU NIS2 Directive Covers chemicals and several kinds of manufacturing in EU member states. Relevant if you have EU sites.
IEC 62443 The standard series for securing industrial control systems, used for risk assessment, network design and supplier requirements.

How ControlShield helps manufacturers

  • COMAH and OG86 readiness. A cyber security management system and evidence that match what HSE inspectors ask for. Regulatory assistance
  • IEC 62443 risk assessments. Identifying your most critical systems and the practical changes that reduce risk most. Risk assessments
  • Separating IT from OT. Designing zones and conduits so a business network incident doesn't stop production. Project lifecycle support
  • Incident response for OT. Plans that cover the plant, not just the office, and that your operators have practised. Consultancy services
  • Supplier and customer requirements. Writing security requirements for machine builders, and preparing evidence when your own customers ask.

What carries over from oil and gas

Our hands-on project work is in upstream oil and gas and downstream gas distribution. Oil and gas facilities are process plants, so most of what we do carries straight over to chemical and process manufacturing:

  • The same control and safety systems. Distributed control systems, PLCs, safety instrumented systems and packaged equipment.
  • Major hazard regulation. Onshore oil and gas terminals and refineries are typically COMAH establishments, inspected by HSE against the same OG86 guidance.
  • Security without stopping production. Advice that works within shutdown windows, management of change and permit-to-work.
  • Security built into projects. We design security in and check it at factory and site acceptance, before handover.

For discrete manufacturing without major hazards, the same IEC 62443 approach applies at a smaller scale. Our guide for small manufacturers explains where to start.

Frequently asked questions

Do manufacturers have to comply with the NIS Regulations?

Most don't. The NIS Regulations 2018 cover energy, transport, health, drinking water and digital infrastructure. Refineries and large oil and gas processing facilities can be in scope through the oil and gas subsectors. Under the Cyber Security and Resilience Bill, regulators will be able to designate critical suppliers, which could include some manufacturers that supply essential services.

Does HSE inspect cyber security at COMAH sites?

Yes. HSE published OG86 in March 2017 and uses it as the benchmark when inspecting control system cyber security at COMAH establishments, as part of how a site controls major accident hazards.

Does the EU Cyber Resilience Act affect UK manufacturers?

It affects anyone who places products with digital elements on the EU market, wherever they are based. Reporting of actively exploited vulnerabilities and severe incidents applies from 11 September 2026, and the main security requirements apply from 11 December 2027.

How do we stop ransomware reaching the plant?

Separate business and control networks with a controlled boundary, remove shared accounts, control remote access, keep offline backups of control system configurations and practise an OT incident response plan. Our ransomware guide covers this in more detail.

Where should a smaller manufacturer start?

With an inventory of your control systems and how they connect to the outside world, then a risk assessment of the most critical. Our free appraisal is a good first step.

Sources

Other sectors we support

Free OT cyber security appraisal

How the free appraisal works

  1. Complete the checklist

    Download the free readiness checklist and work through the 35 questions with your control systems team.

  2. Talk it through

    Send it to us and we'll arrange a free 30-minute call within 10 working days to go through your answers.

  3. Get your next steps

    Within 5 working days of the call, we'll send you a follow-up email with your priorities and suggested next steps.

The appraisal is a conversation and a follow-up email. It is not a formal assessment, audit or regulatory submission. No access to your systems is needed.

Want to know where your plant is exposed?

Free OT cyber security appraisal: complete our readiness checklist, then talk it through with us on a 30-minute call.