Sectors · Power generation and grid

OT cyber security for power generation and the grid

Power stations, substations and electricity networks are controlled by distributed control systems, protection relays and SCADA that can be reached, directly or indirectly, from outside. ControlShield helps generators, network operators and their contractors secure those systems and meet Ofgem's NIS expectations.

Sectors › Power generation and grid

Last checked: 24 November 2026.

The OT cyber risks in power

  • Remote operation of the grid. In December 2015 attackers used stolen credentials and remote access tools to open breakers at three Ukrainian electricity distribution companies, cutting power to about 225,000 customers, according to CISA. Remote access to control systems is still the risk to design out first.
  • Protection and substation systems. Protection relays, substation automation and their engineering laptops are a route to affect the network directly.
  • Plant control systems. Distributed control systems, turbine controls and safety systems at power stations need patching, backups and segregation, often with limited outage windows.
  • Long-term service agreements. Original equipment manufacturers often support turbines and control systems remotely under long contracts.
  • More connected devices. Distributed generation, batteries and flexibility services add devices and platforms that can affect demand and supply.

Which UK rules apply to power

Rule or framework What it means for you
NIS Regulations 2018 (electricity subsector) Duty to manage risks to the network and information systems behind the essential service and to report significant incidents. Nuclear generators are excluded from the generation threshold.
Ofgem NIS guidance for downstream gas and electricity (v3.0, January 2026) How Ofgem expects OES to meet NIS duties and evidence them using the NCSC Cyber Assessment Framework (CAF).
RIIO-3 Cyber Resilience output Funding and reporting route for IT and OT cyber resilience at electricity transmission owners, with a combined re-opener window from 1 to 8 April 2028.
Cyber Security and Resilience Bill Large load controllers in scope, wider incident reporting, higher maximum fines and designated critical suppliers. See our CS&R Bill guide.
COMAH Regulations 2015 and HSE OG86 Apply where a site holds enough dangerous substances, for example large stocks of natural gas or fuel. HSE inspects control system cyber security at COMAH sites against OG86. See our CAF 4.0 and OG86 guide.
IEC 62443 The standard series for risk assessment, design and supplier requirements for control systems.

How ControlShield helps power companies

  • CAF self-assessments and improvement plans for generators and network operators in NIS scope. Regulatory assistance
  • IEC 62443 risk assessments of plant control systems, substations and control centres, with risk reduction recommendations ranked by priority. Risk assessments
  • Security in projects. Cyber requirements for new plant, grid connections and control system upgrades, supplier evidence, and Cyber FAT and SAT. Project lifecycle support
  • Remote access and OEM support. Secure, auditable remote access following the NCSC's secure connectivity principles for OT.
  • Obsolescence planning. Surveying ageing control systems and planning upgrades by risk and business importance. Consultancy services

What carries over from oil and gas

Our hands-on project work is in upstream oil and gas and downstream gas distribution, not power. Much of it carries straight over:

  • The same control and safety systems. Distributed control systems, safety instrumented systems, gas turbines and compressors are common to oil and gas facilities and power stations.
  • Gas as fuel. Gas-fired power stations are supplied by the gas networks we work on, and the two sectors share a regulator in Ofgem.
  • The same regulator and framework. Downstream gas and electricity operators are both regulated by Ofgem under NIS, using the NCSC CAF.
  • Security built into projects. We write security requirements into specifications and check them at factory and site acceptance, before handover.

Frequently asked questions

Is my power station in scope of NIS?

In Great Britain, generation is in scope through the electricity supply threshold: an electricity undertaking that supplies electricity and whose generation, together with affiliated companies, totals 2 gigawatts or more of transmission-connected capacity. Nuclear generators and generators not connected to the transmission system are excluded from that threshold. DESNZ can designate other operators.

Are electricity distribution networks covered?

Yes. Distribution system operators in Great Britain that could disrupt supply to more than 250,000 final customers meet the NIS threshold, as do transmission operators at the same level.

Who regulates cyber security for electricity?

DESNZ and Ofgem act jointly as the competent authority in Great Britain, with Ofgem carrying out compliance, inspections, incident handling and most enforcement. In Northern Ireland the competent authority is the Department of Finance.

What is a large load controller?

The government describes load controllers as organisations that manage electrical load for smart appliances, for example to support EV charging at peak times. The Cyber Security and Resilience Bill brings large load controllers into scope, with the detail to follow in secondary legislation.

Does HSE's OG86 apply to power stations?

Only where the site is a COMAH establishment, which depends on the dangerous substances held there. For NIS, Ofgem assesses generators against the NCSC CAF, and OG86 is aligned to the same CAF objectives, so the evidence overlaps.

Sources

Other sectors we support

Free OT cyber security appraisal

How the free appraisal works

  1. Complete the checklist

    Download the free readiness checklist and work through the 35 questions with your control systems team.

  2. Talk it through

    Send it to us and we'll arrange a free 30-minute call within 10 working days to go through your answers.

  3. Get your next steps

    Within 5 working days of the call, we'll send you a follow-up email with your priorities and suggested next steps.

The appraisal is a conversation and a follow-up email. It is not a formal assessment, audit or regulatory submission. No access to your systems is needed.

Need to evidence OT security to Ofgem?

Free OT cyber security appraisal: complete our readiness checklist, then talk it through with us on a 30-minute call.